LOL! Before my implant that was another thing doctors wanted me to try. WELL! The pump that they sold me was so large that I do not believe it was for humans. I am well endowed, but geez it was way too big. I got it and threw it in the dumpster. That is something doctors shouldn't even recommend. I think it is just part of the process by insurance companies to try and save money.

Implant is the way to go.
age: 75 First implant around 2001, 59 at the time. AMS 700 Ultrex
revision Dec 2016. 2ND implant 21CM, 1rte AMS 700 LGX MS pump

greyt88
Posts: 31
Joined: Fri Dec 29, 2017 3:31 pm

Re: New to pumping

Postby greyt88 » Fri Apr 20, 2018 11:50 am

bldoink wrote:Without supplementing the pump by one of those methods it takes too long to pump up an acceptable amount in a reasonable time without causing hematoma or edema issues. Using the methods outlined above I can achieve a nice hard erection with a VED./[/url]


Totally agree with this. The biggest issue I've had "pumping for exercise" is petechiae from starting with a completely flaccid penis. With sex, there is stimulation and its a lot easier.
Early 40s old diagnosed with severe venous leak by Dr. Irwin Goldstein, Dr. Arnold Mehlman and my local urologist. Using Pos-T-Vac Boss 2000-2 (battery powered Vacuum Erection Device) since 2005.

francisco
Posts: 43
Joined: Fri May 05, 2017 9:07 pm
Location: Buenos Aires

Re: New to pumping

Postby francisco » Sun Apr 22, 2018 2:26 pm

dtwarren1942 wrote:“A cheap one from a sex shop” could be your problem. Better quality cylinders usually have a wider flanged base edge. LeLuv offers a reasonably priced quality “all in” system for about $80. It includes a pump with a vacuum gauge so you can maintain the vacuum level at a safe level - 4 to 5 in.hg.

Also cylinder sizing is important.

Cylinder sizing according to,LAPump

Girth --> Cylinder Diameter
3.50 to 4.50* --> 1.50
4.75 to 5.25* --> 1.75
5.50 to 6.00* --> 2.00
6.25 to 6.75* --> 2.25
7.00 to 7.50* --> 2.50
7.75 to 8.25* --> 2.75


My flaccid penis is 12cmx11.5cm (4.7inchX4.5inch). In erect goes to 18cmX15cm (7.09incX5.9inch) what Cylinder Diameter would you recommend?
Male 26 years old, From Bs. As. Suffering from ED since April '17.

AMS Pumper
Posts: 4
Joined: Mon Apr 09, 2018 5:54 pm

Re: New to pumping

Postby AMS Pumper » Tue Apr 24, 2018 8:12 pm

Any advice pumping after implant surgery? Do you pump up the implant prior to using the VED? I used a VED prior to prostate removal and prior to my implant. My doctor gave me the ok to use the VED although he did not give any direction.
57 year old gay male, retired hotel entrepreneur. Had a AMS 700 21 plus 2 rte installed march 2, 2018 with a Scrotal web reduction, Dr Mills UCLA. I live San Diego and LA. Had prosate removed 2015, shots quit working.

MikeAN
Posts: 60
Joined: Wed Jun 28, 2017 3:55 am
Location: Texas USA

Re: New to pumping

Postby MikeAN » Wed Apr 25, 2018 9:38 am

Do a search under implants "Using your VED after implantation"
1950. Implanted November 1st 2017 by Dr Andrew Kramer with Titian 22cm + 2cm RTE. Pump relocated and replace with Classic pump Jan. 24th, 2018. Pump failure 12/18, Replaced 2/13/19 by Dr Kramer. Revision by Dr Clavell, Feb 28, 2024.

dtwarren1942
Posts: 1909
Joined: Wed Oct 27, 2010 7:58 pm
Location: Jersey Shore

Re: New to pumping

Postby dtwarren1942 » Wed Apr 25, 2018 2:21 pm

francisco wrote:
dtwarren1942 wrote:“A cheap one from a sex shop” could be your problem. Better quality cylinders usually have a wider flanged base edge. LeLuv offers a reasonably priced quality “all in” system for about $80. It includes a pump with a vacuum gauge so you can maintain the vacuum level at a safe level - 4 to 5 in.hg.

Also cylinder sizing is important.

Cylinder sizing according to,LAPump

Girth --> Cylinder Diameter
3.50 to 4.50* --> 1.50
4.75 to 5.25* --> 1.75
5.50 to 6.00* --> 2.00
6.25 to 6.75* --> 2.25
7.00 to 7.50* --> 2.50
7.75 to 8.25* --> 2.75


My flaccid penis is 12cmx11.5cm (4.7inchX4.5inch). In erect goes to 18cmX15cm (7.09incX5.9inch) what Cylinder Diameter would you recommend?

Based on chart, I recommend a 2” cylinder.
Age 81
Diabetic
Pumping
Started Trimix injections 8/'11

francisco
Posts: 43
Joined: Fri May 05, 2017 9:07 pm
Location: Buenos Aires

Re: New to pumping

Postby francisco » Wed Apr 25, 2018 8:45 pm

dtwarren1942 wrote:
francisco wrote:
dtwarren1942 wrote:“A cheap one from a sex shop” could be your problem. Better quality cylinders usually have a wider flanged base edge. LeLuv offers a reasonably priced quality “all in” system for about $80. It includes a pump with a vacuum gauge so you can maintain the vacuum level at a safe level - 4 to 5 in.hg.

Also cylinder sizing is important.

Cylinder sizing according to,LAPump

Girth --> Cylinder Diameter
3.50 to 4.50* --> 1.50
4.75 to 5.25* --> 1.75
5.50 to 6.00* --> 2.00
6.25 to 6.75* --> 2.25
7.00 to 7.50* --> 2.50
7.75 to 8.25* --> 2.75


My flaccid penis is 12cmx11.5cm (4.7inchX4.5inch). In erect goes to 18cmX15cm (7.09incX5.9inch) what Cylinder Diameter would you recommend?

Based on chart, I recommend a 2” cylinder.


Appreciatte my friend!
Male 26 years old, From Bs. As. Suffering from ED since April '17.

KevinWha
Posts: 7
Joined: Mon Jun 25, 2018 5:50 am

Re: New to pumping

Postby KevinWha » Thu Jul 05, 2018 4:08 am


DougAnd
Posts: 1536
Joined: Sun Jul 08, 2018 5:10 pm
Location: Melbourne, Florida

Re: New to pumping

Postby DougAnd » Sat Jul 14, 2018 10:48 pm

I bought 2 different pumps both cost about $13 online w/free shipping. They were called starters. One had a ball the other a hand pump. No instructions. One was 2" diam and the other 2 1/4". I am about 2 1/4" so I fill the 2" side to side. The ball is safer but slower. I blistered my glans twice with the hand pump on 15 min a day. The first time 60% was blistered and the largest one exploded! 2 hours later I had to go into work. That was fun. The 2" one is easy to use,I just ride it high on my pubic bone and my balls are never sucked inside. The 2 1/4" one, well watch out. I have to hold onto my jewels when I start and then its ok. But ride it just as high up onto your belly as possible and hang onto your balls. If not trust me hurts like hell! I do 3 sets of 5 AM and 3 sets of 5 PM. So 5 pressure 5 release 5 pressure 5 release 5 pressure and done. Takes about 30 min.
LGX 18cm+3cmRTE 8 / 8/18 by Docs Saracino , Prody of FL Disfigured by Implant. Married 31 years, Functionally impotent 2+ years. 4" day of surgery now 7" inflated after VED 6.5" without. Pump moved 12/4/18 by Dr Kata

olie20
Posts: 38
Joined: Fri Mar 15, 2013 8:53 am

Re: New to pumping

Postby olie20 » Sat Sep 29, 2018 11:01 am

I got my VED the other day and practiced with it. I found the tube works better with the silicone ring at bottom left off. I shave my pubes so getting a seal isn't a problem. Well last night I had sex with my wife with a large beautiful erection. It had been about 10 years since i had pleasurable sex and 5 years with no sex. It was fantastic, my wife loved it.

One thing to note if you go onto Amazon and buy one of the cheaper pumps it comes from China. Well it took about 3 weeks to get here. I was so pissed that I tried to cancel the order so I could buy an American made one from one of the better know manufacturer. But by that time it was already on the ship so I had to just wait. But its here and it works pretty good. Still have to get a loading cone for it because none was supplied. My next step, if the VED does not correct my ED I am headed to Baltimore to get a penile implant from Dr. Kramer. Then I know I wont have any more problems.


Return to “Pumps (Vacuum Erection Device)”

Who is online